Sign In | Join Free | My burrillandco.com
Home > Energy Storage Power Aging Test Equipment >

Aging Test Of Portable Power Supply Device Stores Electrical Energy

    Buy cheap Aging Test Of Portable Power Supply Device Stores Electrical Energy from wholesalers
     
    Buy cheap Aging Test Of Portable Power Supply Device Stores Electrical Energy from wholesalers
    • Buy cheap Aging Test Of Portable Power Supply Device Stores Electrical Energy from wholesalers
    • Buy cheap Aging Test Of Portable Power Supply Device Stores Electrical Energy from wholesalers
    • Buy cheap Aging Test Of Portable Power Supply Device Stores Electrical Energy from wholesalers

    Aging Test Of Portable Power Supply Device Stores Electrical Energy

    Ask Lasest Price
    Brand Name : CPET
    Model Number : CP-CN05
    Price : 8200dollars/set
    Payment Terms : L/C
    Supply Ability : 30sets/month
    Delivery Time : 35 work days
    • Product Details
    • Company Profile

    Aging Test Of Portable Power Supply Device Stores Electrical Energy

    Aging Test Of Portable Power Supply Device That Stores Electrical Energy


    Outstanding functions


    1. Charge Control System
    Software control program-controlled power supply, freely set voltage to charge energy storage power supply
    2. Charge monitoring system
    The software can monitor the voltage and current in the process of charging the energy storage power supply by the program-controlled power supply and calculate the charging power
    3. AC discharge monitoring system
    Monitor the voltage and current parameter specifications when the AC output of the energy storage power supply is discharged
    4. AC to DC system
    By monitoring the AC output parameters, the load value of the back-end DC load is automatically calculated and set
    5. Multiple load combinations
    Support multiple load combinations to configure the burn-in cabinet
    Performance parameters

    Burn-in cabinet structure
    and Burn-in quantity
    planning
    Trolley size (mm)L2050*W880*H2050mm (size of a single Burn-in cabinet)
    Number of trolley layers4 layers, product area depth 400mm, (12 Burn-in positions per layer)
    Trolley height350mm
    Trolley structure material/appearance color2.0mm thick cold rolled sheet, computer white
    Load area cooling methodTop turbine exhaust fan top row type (easy to control the ambient temperature)
    Layer insulation and anti-static methodEpoxy insulation board with heat dissipation holes on the surface
    Overall burn-in room structureAdopt mobile Burn-in split cabinet; beautiful appearance and easy to move and combine
    Introduction to energy
    recovery module
    configuration, power
    of the tested power
    supply and Burn-in
    quantity
    Energy recovery module control methodRS485 communication mode, upper computer RS232 communication mode
    Install energy consumption module modelCP8118
    Number of installed energy consumption modules8 sets of 8CH modules per layer, 32 sets of Burn-in cabinet need to be installed
    Install energy recovery module modelCP8506 +CP5302
    Energy recovery module isolation methodElectronic load module channel adopts photoelectric isolation (communication and power supply isolation)
    Number of installed energy recovery modules4 sets of 8CH energy recovery modules per floor, 8 sets of the entire Burn-in cabinet need to be installed, 6 sets of 5KW single phase grid-connected inverter modules are installed
    Energy recovery module design frameworkNo relay, long-life design scheme (independent intellectual property rights)
    Number of burn-in products in the whole cabinetSingle cabinet Burn-in 8 DC output (50W/100V/5A) AC output (220V/500W) below 32 energy storage power supplies
    Introduction of electric
    control and temperature
    control device for power
    Burn-in cabinet
    WiringCustomer specified interface; input port is pin socket
    Panel function keysInput AC voltage display, start switch, emergency stop switch
    Trolley power distribution and control mode380V three-phase five-wire power distribution; computer monitoring and automatic electric control
    Trolley power distributionA single Burn-in cabinet 500W*32 sets/0.85≒20KW, the measured power efficiency is calculated at 85%
    Way to controlThe electric control includes manual/automatic switching, and it is monitored by the computer in real time when it is Burn-in.The electric control cabinet can expand the automatic switching function of AC voltage
    Safety protectionEquipment grounding protection, leakage switch protection, smoke alarm automatic power-off protection, etc.
    Introduction to the
    main functions of
    the system
    Applicable to energy storage power,current converter, inverter, regurgitator,transverter, medical power supply and so on
    Free configuration of self-developed special monitoring software for power Burn-in, with independent intellectual property rights and no legal risks
    Use programmable electronic load module to monitor output terminal voltage, current and power parameters
    Dedicated monitoring software for Burn-in enjoys free final upgrade service, powerful expansion function, saving repeated investment in equipment
    Burn-in parameters, time setting, ON/OFF sequence editing (test of the product being tested on and off), support for automatic voltage switching, load
    conversion and other functions can be programmed (Burn-in parameters can be automatically switched in a fixed time period)
    The function of automatically turning off the power at the end of the Burn-in of the tested power supply is convenient for unattended
    The computer automatically displays the quality of the tested power supply product, and multiple windows in the window are convenient for centralized
    management, which saves operators and improves production efficiency
    The computer can store the Burn-in data report of the tested power supply, the process parameters of the tested power supply are easy to trace
    RS232 to RS485 adopts photoelectric isolation converter to improve communication reliability and prevent lightning damage to equipment
    Each computer can monitor 18 devices at the same time, (each serial port can connect to 63 slaves, and each computer supports up to 18 serial ports)
    The power Burn-in monitoring software has a built-in help file, which is convenient for solving operation questions immediately
    Quality Aging Test Of Portable Power Supply Device Stores Electrical Energy for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen CPET Electronics Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)