Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | CPET |
Model Number : | CP-CNF02 |
Price : | 8600dollars/set |
Payment Terms : | L/C |
Supply Ability : | 30sets/month |
Delivery Time : | 40 work days |
Discharge Burn-In Test Equipment For Portable Energy Storage PCS
BMS EMS
Burn-in cabinet structure and Burn-in quantity planning | Trolley size (mm) | L2050*W700*H2050mm (size of a single Burn-in cabinet) |
Number of trolley layers | 4 layers, product area depth 400mm, (12 Burn-in positions per layer) | |
Trolley height | 350mm | |
Trolley structure material | thick cold rolled sheet | |
Load area cooling method | Top turbine exhaust fan top row type (easy to control the ambient
temperature) | |
Layer insulation and anti-static method | Epoxy insulation board with heat dissipation holes on the surface | |
Overall burn-in room structure | Adopt mobile Burn-in split cabinet; beautiful appearance and easy
to move and combine | |
Introduction to energy recovery module configuration, power of the tested power supply and Burn-in quantity | Energy recovery module control mode | RS485 communication mode, upper computer uses RS232 communication
mode |
Install the power module model | CP8401/CP8104 | |
Number of energy-consuming load modules installed | Each layer has 6 4CH modules, and 24 modules need to be installed in the whole burn-in cabinet | |
Install the energy recovery module model | CP8401+CP5301 | |
Energy recovery module isolation mode | Electronic load module channel adopts photoelectric isolation
(communication and power supply isolation) | |
Energy recovery module design architecture | No relay, long-life design scheme (independent intellectual
property rights) | |
Number of burn-in products in the whole cabinet | 24 energy storage power supplies with eight DC outputs
(50W/100V/5A) and AC outputs (220V/500W) are aged in one cabinet | |
Introduction of electric control and temperature control device for power Burn-in cabinet | Wiring | Customer specified interface; input port is pin socket |
Panel function keys | Input AC voltage display, start switch, emergency stop switch | |
Trolley power distribution and control mode | 380V three-phase five-wire distribution; Computer monitoring and
automatic electric control | |
Trolley power distribution | A single burn-in cabinet is 1200W*24/0.85≈34KW, and the measured
power efficiency is calculated as 85% | |
Way to control | The electric control includes manual/automatic switching, which is
monitored by the computer in real time when burn-in. The electric
control cabinet can extend the automatic switching function of AC
voltage | |
Safety protection | Equipment grounding protection, leakage switch protection, smoke
alarm automatic power-off protection, etc. |
![]() |